{"product_id":"hanwest-han-l62-control-set-with-10m-cable-re390","title":"Hanwest HAN-L62 Ducted Air Conditioner Control Kit with 10m Cable | RE390","description":"\u003ch2\u003eHanwest HAN-L62 Two-Stage Heat Pump Air Conditioning Control Kit – 10m Cable\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eHanwest HAN-L62\/PCB-132HP\/10\u003c\/strong\u003e is a microprocessor-based control set for compatible reverse-cycle (heat pump) ducted, split and packaged air conditioning equipment. This kit includes the wall-mounted controller, PCB-132 relay board housed in a vented enclosure, indoor coil warm-up sensor and 10 metre interconnecting lead.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e RE390 | \u003cstrong\u003ePrice:\u003c\/strong\u003e $450.00 including GST | \u003cstrong\u003eAvailability:\u003c\/strong\u003e Supplied to order, subject to supplier stock.\u003c\/p\u003e\u003ch3\u003eController features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e7-day programmable timer with up to six on\/off programs\u003c\/li\u003e\n\u003cli\u003eCooling, heating and automatic operation modes, subject to system configuration\u003c\/li\u003e\n\u003cli\u003eThree-speed indoor fan control with automatic and constant fan options\u003c\/li\u003e\n\u003cli\u003eBacklit LCD with room temperature display\u003c\/li\u003e\n\u003cli\u003e12-hour on\/off countdown timer and sleep function\u003c\/li\u003e\n\u003cli\u003eKey-lock function\u003c\/li\u003e\n\u003cli\u003eSupport for up to four wall controllers in master\/slave configuration\u003c\/li\u003e\n\u003cli\u003eSupport for up to four optional remote temperature sensors\u003c\/li\u003e\n\u003cli\u003eOptional six-zone damper control with separate PCB-086 zone relay board\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded in the RE390 kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHAN-L62 wall controller and mounting plate\u003c\/li\u003e\n\u003cli\u003ePCB-132 power relay board fitted inside PBEC-L62 vented enclosure\u003c\/li\u003e\n\u003cli\u003eOne indoor coil system warm-up sensor\u003c\/li\u003e\n\u003cli\u003e10 metre shielded interconnecting cable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications and compatibility\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eManufacturer part number:\u003c\/strong\u003e HAN-L62\/PCB-132HP\/10. \u003cstrong\u003eApplication:\u003c\/strong\u003e compatible one- or two-stage heat-pump\/reverse-cycle air conditioning systems. Optional 20m cable, additional sensors and PCB-086 zone board are not included. For two-stage installations an additional coil sensor may be required.\u003c\/p\u003e\u003cp\u003eCheck the existing controller, relay board, electrical supply, terminal configuration and equipment wiring before ordering. The HAN-L62HP heat-pump kit must not be confused with the HAN-L62EH electric-element heating variant.\u003c\/p\u003e\u003ch3\u003eWiring diagram and installation documents\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/attachments.hvacrworld.au\/products\/files\/RE390%5B1875%5D.pdf?r=1710738622\" target=\"_blank\" rel=\"noopener\"\u003eDownload Hanwest HAN-L62 \/ PCB-132 typical wiring diagram (PDF)\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003eThe manufacturer wiring diagram covers the PCB-132 main control board, compressor contactors, reversing valves, indoor fan connections, optional sensors, wall control and DIP-switch settings. The supplied shielded interface cable must be terminated according to the relevant manufacturer instructions. \u003cstrong\u003eImportant:\u003c\/strong\u003e This diagram is a typical reference only; the installer must verify the exact equipment wiring and controller revision before connecting power. Installation and electrical work must be performed by suitably licensed personnel.\u003c\/p\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes this include the control board?\u003c\/strong\u003e Yes, the PCB-132 power relay board is included in its enclosure.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the kit include a cable?\u003c\/strong\u003e Yes, a 10m interconnecting cable is included.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it control zones?\u003c\/strong\u003e Yes, with an optional PCB-086 zone relay board, sold separately, for up to six compatible zone dampers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I use it with any air conditioner?\u003c\/strong\u003e No. Check equipment and wiring compatibility before ordering.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs it held in stock?\u003c\/strong\u003e This is a supplier-order item. Dispatch timing depends on availability.\u003c\/p\u003e","brand":"Hanwest","offers":[{"title":"Default Title","offer_id":68660112097586,"sku":"RE390","price":450.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0633\/1577\/files\/56858.jpg?v=1794537502","url":"https:\/\/shop.ptea.com.au\/products\/hanwest-han-l62-control-set-with-10m-cable-re390","provider":"Palm Tree Enterprise Australia","version":"1.0","type":"link"}