Daikin FDYUA71A-V 7.1kW Premium Inverter Underfloor Ducted AC System 1 Phase

by Daikin
$4,650.00

Daikin's Underfloor Ducted Systems offer an excellent heating solution for homes located in colder climates. These systems are specifically designed to distribute warm air evenly throughout the entire home, making them highly suitable for such environments. Moreover, Daikin has upgraded these systems to use R32 refrigerants, reducing their global warming potential (GWP). By combining Daikin's Underfloor Systems with their Zone Controllers, homeowners can achieve optimal energy performance and enhance their overall comfort at home, without compromising aesthetics.

Specification :

INDOOR UNIT FDYUA71AV1
OUTDOOR UNIT RZAS71C2V1
Rated Capacity cool (kW) 7.1
Heat (kW) 7.5
Capacity Range Cool (kW) 3.2-8.0
Heat (kW) 3.5-9.0
Power Input (Rated) cool (kW) 1.9
Heat (kW) 1.75
E.E.R/C.O.P C/H 3.74/4.29
TCSPF (Residential) Hot/Average/Cold 5.21/4.52/4.58
HSPF (Residential) Hot/Average/Cold 3.87/3.80/3.51
Airflow Rate (Nominal/Max) I/s 425/566
Indoor Sound Level (H) @ 1.5m dBA (C/H) 37.3/40.5
Piping Length m 75
Indoor Fan Speeds H/M/L
Dimensions (HxWxD) Indoor (mm) 300x1210x900
Outdoor (mm) 990x940x320
Weight Indoor (kg) 40
Outdoor (kg) 69
Power Supply V/HZ 1 Phase, 220-240V, 50Hz
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Pipe Sizes Liquid (mm) 9.5 (Flared)
Gas (mm) 15.9 (Flared)
Drain (mm) ID 25 / OD 32
Supply Air Opening mm (HxW, Flange) 185×852
Return Air Opening mm 1×400 (Oval)
Outdoor Operating Range cool (OCDB) -5 to 50
Heat (OCWB) -15 to 16
EPA Sound Power Level dBA 67
Outdoor Sound Level (H) @ 1m Pressure dBA (C/H) 48/50

 