MITSUBISHI ELECTRIC PEAM100GAAVKIT 10.0kW Ducted Air Conditioner System 1 Phase
by Mitsubishi Electric
$3,950.00
- Accessories and options are available so that you get the system that suits you
- Powerful yet extremely quiet operation
- High static pressure fans means that even when connected to lengthy ductwork, the volume of airflow is maintained to keep your living environment comfortable at all times
- All systems incorporate the latest referigerant R410A
- Lightweight and compact means it is easy to install in limited roof space
- Super quiet operation during the day and even quieter at night
- Guaranteed operation for outdoor temperatures of -20ºC for heating and up to 46ºC for cooling
- Long refrigerant piping allows even greater flexibility in the location of the outdoor unit
- Uses the PAR-21MAA system controller for weekly scheduled operation
- Self-diagnostic function in the unlikely event of a system malfunction.
Specification :
Indoor Unit | PEA-M100GAA | |||
Outdoor Unit
Refrigerant |
PUZ-ZM 100VKA | |||
R32 | ||||
Power Supply |
Source | Outdoor power supply | ||
Outdoor |
V: 230V, Single-phase, 50Hz Y: 400V, Three-phase, 50Hz |
|||
Indoor | – | |||
Cooling Heating |
Capacity
[Min-Rated-Max] |
(kW) | 4.9-10.0-11.4 | |
Total Input [Rated] | (kW) | 2.39 | ||
AEER/EER | 4.01 / 4.18 | |||
AEER [Part-load %] *1 | – | |||
Running Current [Rated] |
A |
11.30 |
||
Sound | In (Lo-Mid-Hi) |
dB(A) |
39 – 42 | |
Pressure
Level |
Out (PWL) | 49 (69) | ||
Air Volume (In) Lo-Mid-Hi L/S | 567 – 700 | |||
Capacity
[Min-Rated-Max] |
(kW) | 4.5-11.2-14.0 | ||
Total Input [Rated] | (kW) | 2.51 | ||
ACOP/COP *3 | 4.28 / 4.46 | |||
Running Current [Rated] | (mm) | 11.50 | ||
Sound Pressure | In (Lo-Mid-Hi) | dB(A) | 39 – 42 | |
Level | Out (PWL) | dB(A) | 51 (69) | |
Air Volume (In) Lo-Mid-Hi | 567 – 700 | |||
Max. Running Current | A | 30.78 | ||
Input [Rated] | kW | 0.21 / 0.21 | ||
Indoor Unit | Dimensions [HxWxD] | mm | 400 × 1400 × 634 | |
Weight | kg | 63 | ||
Static Pressure | Pa | 50 / 100 / 150 | ||
Outdoor Unit |
Dimensions [HxWxD] | mm | 1338 × 1050 × 330 (+40) | |
Weight | kg | 113 | ||
Breaker Size | A | 32 | ||
Ext. Piping | Diameter [Gas/Liquid] | mm | 15.88 / 9.52 | |
Max. Length/Height | m | 75 / 30 | ||
Guaranteed Operating Range [Outdoor] | Cooling *2 | °C | -5 (-15) ~ 52 | |
Heating | °C | -20 ~ 21 | ||
Supply Air Duct | mm | 921 x 250 | ||
Return Air Duct | mm | 1102 x 330 | ||
Precharge Refrigerant | kg | 4 (30m) | ||
Additional Refrigerant | Per M (g) | 60 |